修正朝上判断、接触高度与过期姿态目标

朝上判断误用平台轴、接触高度报旋转前数值、多点对准复用缓存姿态,且多点会话被复核入口拒绝;
现按修正计划改正并接通 autocal-multipoint-1.0 只读复核,缺失帧源如实报告而不补零。

离线验证:新回归在 dc5a6f8 上失败、此处通过,panel_check 通过,两截图点接触高度复现
19.0510 / 21.5781 mm;实机项未做,详见 .scratch/autocal-motion-fix/verification.md。
This commit is contained in:
ykcheungab
2026-10-15 06:52:28 +08:00
parent 5339624ffa
commit bcc55a3b97
29 changed files with 2179 additions and 209 deletions
+7 -1
View File
@@ -24,14 +24,20 @@
"max_travel_mm": 100.0,
"max_descent_mm": 10.0,
"max_press_depth_mm": 1.0,
"max_yaw_deg": 180.0,
"max_pitch_deg": 90.0,
"follow_error_mm": 0.5,
"contact_search_mm": 3.0
},
"press_axis": {
"zero_mm": 0.0,
"rising": true,
"calibrated": false
},
"sensor_setup": {
"sensor_type": "box",
"config_ref": "",
"geometry_id": "",
"press_axis": 2,
"probe_tip_offset_mm": [0.0, 0.0, 0.0],
"probe_tip_set": false,
"sensor_to_platform": [],