Files
orisys-app/apps/autocal/README.md
T

9.5 KiB
Raw Blame History

Orisys AutoCal

Internal control application for the 5-axis calibration platform, driving a ZMotion ZMC bus controller (EtherCAT or RTEX) from the PC.

Replaces the vendor example program it was ported from:

D:\orisys_ws\zmotion\Python64\例程9-总线控制运动

Internal use only. AutoCal is not part of the customer installer. See "Do not ship this app" below.

What it does

  • Connect over Ethernet (with an IP scan), serial, PCI, local/simulated, or a built-in demo transport that needs no hardware and no DLL.
  • Initialise the bus by downloading ECAT.bas or RTEX.bas to the controller, then follow the controller's own state machine to completion — or to a timeout, with the vendor's diagnostic hint.
  • Read axis state for all five drives at once: enable, axis type, pulse equivalent, speed, acceleration, commanded and measured position (in user units and millimetres), axis status word, motion and homing state.
  • Move: enable/disable, jog, absolute and relative moves, stop, stop-all, driver homing, clear a drive alarm. Every command is guarded — see below.
  • Exchange raw bus data: EtherCAT object-dictionary (SDO) reads and writes, and RTEX parameters. Each family is enabled only when the controller reports that bus type.

Run it

PySide6 only — Qt's LGPLv3 binding, so an internal closed-source tool needs no licence purchase. (PyQt5 is GPLv3-or-commercial; the studio app moved to PySide6 for the same reason and no longer uses it.)

# with the environment that already has PySide6 (Anaconda py310, for example)
$env:PYTHONPATH = "D:\orisys_ws\orisys-app\shared\src;D:\orisys_ws\orisys-app\apps\autocal\src"
python D:\orisys_ws\orisys-app\apps\autocal\run.py

Or with no controller attached at all:

python .\apps\autocal\run.py --demo

run.py sets ORISYS_APP_ID=autocal before importing anything from orisys_app_shared, so this app's config/, preference.json and outputs/ resolve to apps/autocal/ rather than the studio's.

Controller library

The ZMotion runtime is vendored at shared/resources/zmotion/x64/ (see the README beside it for provenance). Point ORISYS_ZMOTION_DLL_DIR at another directory to use a different build — on a motion controller, silently loading the wrong runtime version is the kind of fault that looks like a working machine until it moves, so the override is authoritative: if it does not contain zauxdll.dll, the app refuses to connect instead of quietly falling back.

One contract in shared/src/orisys_app_shared/zmotion/client.py is worth knowing before touching it: ZAux_Execute must be given a reply buffer. Passing NULL with a zero length is a write through a null pointer inside the DLL — a native crash the worker thread cannot catch — and the buffer is also how a refused online command explains itself, because ZAux_Execute returns 0 for a RUN whose file the controller does not have.

Bring-up sequence

The vendor sequence, with the checks AutoCal's own state machine adds. P1 of docs/workflow.md is this list in the workflow's vocabulary.

  1. Connect (eth + the controller's IP). On success the app adopts any BAS program the controller is already running from a previous session instead of claiming the bus is uninitialised; BUS_TYPE is read immediately, and Bus_InitStatus on the first poll.
  2. Download only if the bus type is unknown. ECAT.bas / RTEX.bas are chosen from config/bas/ (the vendor requires a non-Chinese path) and written to ROM. A controller that still has the program needs no download.
  3. Wait for Bus_InitStatus — −1 running, 1 success, 0 failed — inside the vendor's 25 s window, then a timeout message naming the ZDevelop diagnostic (?*ETHERCAT).
  4. Re-initialise re-runs the program without re-downloading it: STOPTASK <task> then RUN "<file>",<task>. The task number is bas_task in preference.json (default 4, the task the vendor reference uses); the file name comes from this session's download, or from the remembered bas_path when the session adopted a running program (the controller does not report the name). The controller answers a RUN for a file it does not have with code 0 and the refusal in its reply text, so that text is checked and shown rather than reported as an initialisation in progress.
  5. Enable, then jog. Motion stays refused until step 3 reports success.

Connection and error codes

ZAux_* returns two unrelated families of code, and they need different answers:

Range Family What the operator should do
0 success —
20000–29999 PC-library fault (handshake, socket, address) check the cable/segment and the IP, make sure nothing else holds the connection, then retry. Frequently transient: a first open on a cold route can fail and succeed on the next attempt, which is why an Ethernet connect makes up to 3 attempts before reporting.
30000+ the auxiliary block zauxdll2.h documents the message names it (无应答, 参数错误, …)
anything else the controller's own code look it up in ZDevelop's table

A host-library code is never sent to ZDevelop's table, because that table cannot contain it. Observed at the bench: 20008 from ZAux_OpenEth on a first, transient attempt that succeeded immediately afterwards.

Safety model

The guards live in motion/service.py, not in the UI, so they hold whatever calls them:

  • Motion is refused while the bus is not initialised, while the axis is unknown, or on a non-finite target — with a reason, never a silent no-op.
  • Homing needs a configured mode. The vendor example pre-fills 17, which is one specific drive's mode; AutoCal starts at 0 and refuses, so the operator chooses for the drive in front of them instead of inheriting a number from another machine.
  • Homing is refused on RTEX, as the vendor example itself does.
  • Disconnect stops the axes first (the vendor program closes the handle and leaves the platform coasting).
  • SDO/RTEX are gated by the reported bus type, so a write can never be aimed at the wrong family.
  • A failed read is marked, not zeroed. ZmotionValue.value_or_none returns None on failure; nothing silently treats a failed read's zero as a position.

The displayed millimetre value is derived from the pulse equivalent (bench-measured: units=10 → 1000 user units = 2 mm). It is a display value, not a calibrated length, and the UI says so.

Layout

apps/autocal/
  run.py                     # source-tree launcher
  config/
    preferences.default.json # shipped defaults
    locales/{zh_CN,en_US}.json
    bas/{ECAT,RTEX}.bas      # copies: the vendor needs a non-Chinese path
  src/orisys_autocal/
    main.py                  # logging, locale, theme, window
    preferences.py           # AutoCal's own preference schema
    motion/                  # Qt-free except poller.py (the Qt worker bridge)
      models.py errors.py units.py service.py transport.py poller.py
    ui/                      # window.py + one module per panel
  tools/                     # panel_check.py, panel_snapshot.py
  tests/

motion/poller.py is the only place a controller call can originate. It owns the DLL handle on its own thread, so the vendor library's blocking calls (a ROM write, a bus scan) never freeze the window and the ctypes handle is never shared between threads. The UI talks to it through signals only.

Verify

Both work with no display, no controller and no DLL:

python .\apps\autocal\tools\panel_check.py     # 120 layout/theme/locale/gating checks
python .\apps\autocal\tools\panel_snapshot.py --demo --theme dark --out shot.png
python .\apps\autocal\tools\panel_snapshot.py --compare --out tabs.png   # one image per tab
python .\apps\autocal\tools\layout_mockup.py --out layout.png            # proposed layout, drawn
python -m pytest apps\autocal\tests            # offscreen suite

layout_mockup.py is a wireframe, not the application: it paints the proposed single-page layout with the shared theme tokens and imports nothing from the app, so the layout can be reviewed and marked up without building the panels. It draws the full page plus previews of the other workspace tabs in one canvas.

panel_check.py builds the real window in both themes at 1280×720, 1600×900 and 1920×1080, asserts that no widget escapes its parent, that motion is unreachable before the bus is initialised, that the SDO/RTEX panels follow the reported bus family, and then runs a full simulated session from ECAT.bas.

The suite is written for PySide6. Where PySide6 is missing, the test modules are skipped rather than failed: a broken environment should not look like a broken application. tests/test_binding_purity.py enforces the binding policy statically — no module may import PyQt5/PySide2/PyQt6, no module may use an unscoped Qt enumerator (removed in PySide6), shared/ may import PySide6 and no other binding, and the controller interface must stay importable headless. The studio app enforces the same rules for itself in apps/studio/tests/test_binding_purity.py.

Do not ship this app

AutoCal is an internal tool. It is deliberately not packaged by build/studio, whose PyInstaller spec must not learn about the ZMotion runtime DLLs, and it is not in the customer installer. The ZMotion SDK is vendor-supplied hardware support software with its own terms; do not redistribute those DLLs with a customer product.