允许 HHD 下采样率不同的标定保持兼容
按实际运行上下文核对其余处理参数,保留文件指纹与设备身份校验。115 项标定及运行时检查通过。
This commit is contained in:
@@ -52,7 +52,7 @@ _KNOWN_TOP_KEYS = frozenset(
|
||||
#: Filter stages that change **what is measured**: they sit upstream of the
|
||||
#: force computation, so two recordings with different values are not comparable.
|
||||
#: They belong to the measurement-pipeline identity, for the same reason
|
||||
#: ``dis_mode`` and ``hhd_downsample`` do.
|
||||
#: ``dis_mode`` does. HHD resolution is retained in provenance but may differ.
|
||||
FILTER_MEASUREMENT_KEYS: tuple[str, ...] = ("flow_ema_alpha",)
|
||||
#: Filter stages that only smooth the force triple on its way out. They are
|
||||
#: recorded so a file explains its own numbers, but a difference between two
|
||||
@@ -876,7 +876,7 @@ def validate_for_device(
|
||||
*,
|
||||
pipeline: Mapping[str, Any] | None = None,
|
||||
) -> Calibration:
|
||||
"""Reject a calibration for another device or measurement pipeline."""
|
||||
"""Reject a different device or pipeline, allowing HHD resolution differences."""
|
||||
path = cal.source_path or "<in-memory calibration>"
|
||||
if cal.identity.get("sensor_type") != sensor_type or cal.identity.get("sn") != device_id:
|
||||
raise CalibrationError(f"calibration identity mismatch: {path}")
|
||||
@@ -886,7 +886,7 @@ def validate_for_device(
|
||||
# Full feature/geometry validation happens when the processor binds its
|
||||
# actual context. Device construction only knows this legacy subset.
|
||||
if pipeline is not None:
|
||||
for key in ("stitch_resolution", "dis_mode", "hhd_downsample"):
|
||||
for key in ("stitch_resolution", "dis_mode"):
|
||||
if pipeline.get(key) is not None and cal.pipeline.get(key) != pipeline[key]:
|
||||
raise CalibrationError(f"calibration pipeline mismatch ({key}): {path}")
|
||||
measurement, _ = filter_mismatches(cal.pipeline.get("filters"), pipeline.get("filters"))
|
||||
@@ -898,7 +898,7 @@ def validate_for_device(
|
||||
if set(CHANNEL_IDS) - cal.channels.keys():
|
||||
raise CalibrationError(f"calibration requires FN, FX and FY: {path}")
|
||||
if pipeline is not None:
|
||||
for key in ("stitch_resolution", "dis_mode", "hhd_downsample"):
|
||||
for key in ("stitch_resolution", "dis_mode"):
|
||||
recorded, current = cal.pipeline.get(key), pipeline.get(key)
|
||||
if recorded is not None and current is not None and recorded != current:
|
||||
raise CalibrationError(f"calibration pipeline mismatch ({key}): {path}")
|
||||
|
||||
@@ -4,6 +4,7 @@ from __future__ import annotations
|
||||
|
||||
import hashlib
|
||||
import json
|
||||
from copy import deepcopy
|
||||
from pathlib import Path
|
||||
|
||||
import numpy as np
|
||||
@@ -11,6 +12,29 @@ import numpy as np
|
||||
from .calibration import filters_fingerprint
|
||||
|
||||
|
||||
def _feature_signature(identity) -> str:
|
||||
encoded = json.dumps(identity, sort_keys=True, separators=(",", ":"), allow_nan=False)
|
||||
return hashlib.sha256(encoded.encode("utf-8")).hexdigest()
|
||||
|
||||
|
||||
class CalibrationContext(dict):
|
||||
"""Actual pipeline fields plus the runtime inputs needed to compare HHD settings.
|
||||
|
||||
JSON serialization contains only the actual fields. Retaining the signature
|
||||
inputs lets old files differ in downsample without ignoring other hashed settings.
|
||||
"""
|
||||
|
||||
def __init__(self, fields, feature_identity):
|
||||
super().__init__(fields)
|
||||
self._feature_identity = deepcopy(feature_identity)
|
||||
|
||||
def signature_for_downsample(self, downsample: int) -> str:
|
||||
"""Recompute the runtime identity with only the requested HHD resolution."""
|
||||
identity = deepcopy(self._feature_identity)
|
||||
identity["tracker"]["hhd_downsample"] = downsample
|
||||
return _feature_signature(identity)
|
||||
|
||||
|
||||
def sha256_file(path) -> str:
|
||||
return hashlib.sha256(Path(path).read_bytes()).hexdigest()
|
||||
|
||||
@@ -70,6 +94,5 @@ def build_context(config, filters=None, *, geometry_sha256=None, source_scale=No
|
||||
"source_scale": source_scale,
|
||||
"preprocessing": preprocessing or {},
|
||||
}
|
||||
encoded = json.dumps(effective, sort_keys=True, separators=(",", ":"), allow_nan=False)
|
||||
result["feature_signature_sha256"] = hashlib.sha256(encoded.encode("utf-8")).hexdigest()
|
||||
return result
|
||||
result["feature_signature_sha256"] = _feature_signature(effective)
|
||||
return CalibrationContext(result, effective)
|
||||
|
||||
@@ -209,8 +209,19 @@ class ModelCalibration:
|
||||
return deepcopy(self._document)
|
||||
|
||||
def validate_for_context(self, pipeline: Mapping[str, Any]) -> None:
|
||||
from .calibration_context import CalibrationContext
|
||||
|
||||
for key, value in self.pipeline.items():
|
||||
if key == "filters":
|
||||
if key == "hhd_downsample":
|
||||
# HHD magnitudes are normalized to the full flow grid; resolution
|
||||
# can introduce numerical deviations without changing the force unit.
|
||||
continue
|
||||
if key == "feature_signature_sha256" and isinstance(pipeline, CalibrationContext):
|
||||
_require(
|
||||
pipeline.signature_for_downsample(self.pipeline["hhd_downsample"]) == value,
|
||||
"calibration pipeline mismatch: feature_signature_sha256",
|
||||
)
|
||||
elif key == "filters":
|
||||
actual = pipeline.get(key, {})
|
||||
_require(isinstance(actual, Mapping) and actual.get("measurement") == value["measurement"],
|
||||
"calibration pipeline mismatch: filters.measurement")
|
||||
|
||||
Reference in New Issue